taimen: MNH mitigation monitor.

Bug: 119689840
Test: Tested manually using a dummy cooling device
Change-Id: Ib3b35ea73455174cb867fc2655721eb99c382c9e
Signed-off-by: Vincent Palomares <paillon@google.com>
This commit is contained in:
Vincent Palomares
2018-11-19 14:50:23 -08:00
parent 07c73b7a8f
commit 131e79c48e

View File

@@ -57,6 +57,15 @@ thresholds_clr 47000 49000 51000
actions cluster0+cluster1+gpu+report cluster0+cluster1+gpu+report cluster0+cluster1+gpu+report
action_info 1094400+1190400+414000000+1 883200+902400+342000000+1 300000+300000+257000000+1
[MNH-MONITOR2]
algo_type monitor
sampling 2000
sensor bd_therm2
thresholds 48000 50000
thresholds_clr 47000 49000
actions mnh mnh
action_info 3 4
[BATTERY-MONITOR2]
algo_type monitor
sampling 2000
@@ -133,6 +142,15 @@ thresholds_clr 57000 59000 63000
actions cluster0+cluster1+gpu+report cluster0+cluster1+gpu+report cluster0+cluster1+gpu+report
action_info 1094400+1190400+414000000+1 883200+902400+342000000+1 300000+300000+257000000+1
[MNH-MONITOR]
algo_type monitor
sampling 2000
sensor bd_therm
thresholds 58000 60000
thresholds_clr 57000 59000
actions mnh mnh
action_info 3 4
[SKIN-SHUTDOWN]
algo_type monitor
sampling 1000