sampling 5000
[SKIN-MID-FLOOR-BC]
algo_type ss
sampling 2000
sensor back_therm
device cluster1
set_point 40000
set_point_clr 39000
device_perf_floor 1804800
time_constant 0
[SKIN-LOW-FLOOR-BC]
algo_type ss
sampling 2000
sensor back_therm
device cluster1
set_point 42000
set_point_clr 41000
device_perf_floor 1190400
time_constant 0
[HOT-SKIN-VIRTUAL]
algo_type virtual
trip_sensor back_therm
sensors tsens_tz_sensor13 tsens_tz_sensor0
list_cnt 2
weights 1 -1
set_point 39000
set_point_clr 36000
sampling 1000
math 0
[VIRTUAL-SS-GPU-SKIN]
algo_type ss
sensor HOT-SKIN-VIRTUAL
device gpu
sampling 2000
set_point 7000
set_point_clr 2000
device_max_limit 414000000
[SKIN-MONITOR]
algo_type monitor
sampling 2000
sensor back_therm
thresholds 50000 52000
thresholds_clr 49000 51000
actions cluster0+cluster1+gpu cluster0+cluster1+gpu
action_info 1094400+1190400+414000000 883200+902400+342000000
[SKIN-SHUTDOWN]
algo_type monitor
sampling 1000
sensor back_therm
thresholds 56000
thresholds_clr 55000
actions shutdown
action_info 1