From 428d25abfdef88d9eb7d1df565c99eb0557763e8 Mon Sep 17 00:00:00 2001 From: Yu-Han Yang Date: Fri, 14 Feb 2020 11:15:48 -0800 Subject: [PATCH] Update measurement_correction reported accuracy HAL doc Fixes: 144817918 Test: doc only and builds Change-Id: I5aed4a17b5dea8949904f08809d3df9ec250fbeb --- current.txt | 1 + gnss/measurement_corrections/1.0/types.hal | 8 ++++---- 2 files changed, 5 insertions(+), 4 deletions(-) diff --git a/current.txt b/current.txt index 2fa5dcabab..5cbb406ad4 100644 --- a/current.txt +++ b/current.txt @@ -588,6 +588,7 @@ d3a344b7bd4c0d2658ae7209f55a979b8f53f361fd00f4fca29d5baa56d11fd2 android.hardwar cd06a7911b9acd4a653bbf7133888878fbcb3f84be177c7a3f1becaae3d8618f android.hardware.camera.metadata@3.2::types a05277065c28ebecd58118bd240fb8c55757361e8648c01f7c4dacdb7f2a95dc android.hardware.camera.metadata@3.3::types 9cb3df2bde2c6cd5fd96b7c41555420cacd7e276a556c684af91b7461c86460f android.hardware.gnss@1.0::IGnssCallback +af334f1fc85c62b343f84b74d0495eed6f495f7fecedb53463db10c202310058 android.hardware.gnss.measurement_corrections@1.0::types bceee81ec1b59324abd05932b5620fda5a6589597c9cb3953ba7f3ea02cccd3e android.hardware.camera.provider@2.4::ICameraProvider 2ce820dc4f3c6d85721b65150ed2157c6e2e2055f866fb6c6ba4790f14408d66 android.hardware.camera.provider@2.4::ICameraProviderCallback b69a7615c508acf5c5201efd1bfa3262167874fc3594e2db5a3ff93addd8ac75 android.hardware.keymaster@4.0::IKeymasterDevice diff --git a/gnss/measurement_corrections/1.0/types.hal b/gnss/measurement_corrections/1.0/types.hal index edf26bf7c0..3d7ab0f09c 100644 --- a/gnss/measurement_corrections/1.0/types.hal +++ b/gnss/measurement_corrections/1.0/types.hal @@ -92,16 +92,16 @@ struct MeasurementCorrections { double altitudeMeters; /** - * Represents the horizontal uncertainty (68% confidence) in meters on the device position at - * which the corrections are provided. + * Represents the horizontal uncertainty (63% to 68% confidence) in meters on the device + * position at which the corrections are provided. * * This value is useful for example to judge how accurate the provided corrections are. */ double horizontalPositionUncertaintyMeters; /** - * Represents the vertical uncertainty (68% confidence) in meters on the device position at - * which the corrections are provided. + * Represents the vertical uncertainty (63% to 68% confidence) in meters on the device position + * at which the corrections are provided. * * This value is useful for example to judge how accurate the provided corrections are. */